Method of operation
0. Startup steps
1. Start the main power supply
2. Start the inverter power supply
3. Set the frequency of each inverter
4. Start the frequency converter (it can also run automatically)
5. Set microwave power and other parameters
6. Turn on the microwave
7. Observe whether the ammeter and indicator light on the operation panel work normally.
Note: When the equipment is working normally, all green indicators on the control panel should be working. The microwave working indicator or the whole group should be on or off. The needle of the ammeter should be stable without obvious jumping.
Problems that should be paid attention to during equipment use
- Equipment as a whole
The equipment should be kept clean, the circuit part should not have dust, let alone moisture
- Control section
The startup process should be operated in sequence. After each operation is completed, attention should be paid to whether the indicator light and ammeter of the corresponding step work normally. If there is any abnormality, stop the operation and find out the reason
- Microwave circuit section
When the microwave circuit is working, the voltage on the circuit is greater than 4200V. At this time, no one is allowed to try to touch the circuit with any tool. The microwave circuit part shall not be repaired within five minutes after the equipment is shut down, unless it has been discharged.
Special note: Non-professionals are not allowed to touch this part